lh rotation

Vickers PVE 19/21 Hydraulic Pump

convert flange model to foot bracket model you will need FB-B-10 assy 422683   CVP(C)B Compensator This is a right hand rotation (if left hand is need rotate it 180 degrees) Align the compensator, drill thru and put in lockwire thru the seal, next compress seal with the right tool. Black circle = compensator piston […]

Vickers PVE 19/21 Hydraulic Pump Read More »

Rexroth A10VO28 DR(DRG, DFR, DFR1)/52R(L)-VXC61(64)N00 Series 28

        If you need more assistance with this unit or any others, call us at 800-361-0068 sales@htsrepair.com

Rexroth A10VO28 DR(DRG, DFR, DFR1)/52R(L)-VXC61(64)N00 Series 28 Read More »

Racine PVF Variable Volume Vane Pump

  PVF-PSTO-12* *-01 P = Higher Standard Compensator S= look for the diagram for screw volume control B,C,E = look on the diagrams below for parts list for springs R,L,D = see which letter matches up with the letter on your pump code. *goes with bodies 221458 and 221581 only   chart on the right

Racine PVF Variable Volume Vane Pump Read More »

Sundstrand 90 Series 55cc Cage Locator and Auxiliary Flange Charge Pump Cover

They want be putting R for right hand or L for left hand on the flange anymore. Instead the pilot surface is what is changing on the covers. The RH rotation will have 1 step and the LH rotation will have 2 steps. The model it affects is the 90-42cc thru 100 cc pumps that