axial piston pump

Vickers PVE 19/21 Hydraulic Pump

convert flange model to foot bracket model you will need FB-B-10 assy 422683   CVP(C)B Compensator This is a right hand rotation (if left hand is need rotate it 180 degrees) Align the compensator, drill thru and put in lockwire thru the seal, next compress seal with the right tool. Black circle = compensator piston […]

Vickers PVE 19/21 Hydraulic Pump Read More »

Rexroth A6VM/AA6VM Hydraulic Pump – Startup

The motor needs to be filled up with fluid (fill the case chamber), start on low speed and don’t put a load pressure on it til you bleed it out. If not used in awhile, fluid can leak out thru the case in the lines. Fluid needs to be in the lines to start it