Eaton IPOR End Cover – Models 3320 – 7620 & 3321 – 6421 Leave a Comment / cessna, Cylinder Information, dynapower, eaton, hydraulic, motor, neutral lockout switch, packing, packing or seal kit, parker, pump, racine, reservoir, rexroth, seal kit, sundstrand, sundstrand sauer danfoss, swashplate bearing, tie rod end cylinder, torquemotor, vane pump, Vane Pump Information, vee packing / By Andrew Soper The chart at the top left: *SAE Code 61 split flange 3000 PSI – 3/8-16 UNC 2 B thread bolt ** SAE Code 62 split flange 6000 PSI — 7/16 -14 UNC 2B thread bolt Bottom chart *** orifice dia. .028, .036, .044, .052, .057, .065, .073, .094, .102 stake 6 places outer edge for retention To know the pressure range – shim adjustable from 1000 to 6000 PSI Shim .018 = 500 PSI And if you see a NSS that means there is not one sold by itself. Call 662-871-8403 tupelohydraulics@gmail.com